Description
Description: Operating voltage: DC 5-12V(5V 6V 9V 12V) Operating current: 5V, forward 4mA, reverse: 36mA; 12V, forward 6mA, reverse: 44mA Load voltage: DC 1-48V or AC 85-265V Load current: Max 2A Forward max time: 5000 seconds, 0.1 seconds step Reverse max time: 5000 seconds, 0.1 seconds step Size: 54*22*15mm / 2.12*0.87*0.59in Weight: Approx. 15g T1: motor forward delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds) T2: motor reverse delay time, default 0.1-5000 seconds adjustable (step 0.1 seconds) By “Time multiple selection” setting, the maximum delay is up to 40,000 secondsHow to Set Up: After power on, D1 3 blinks, enter the “work mode” D2 on Reversal, D2 off Forward Press and hold the key for 2 seconds, D1 on, enter the “setup mode” D2 off, It’s forward “setup mode” In forward “setup mode”, continuously trigger KEY twice, D1 off, enter “Standby timer mode” In the “Standby timer mode” , trigger KEY to start timing(enter “Timing Mode”) D1 flashing means it is timing(“Timing Mode”) Trigger KEY again to stop the clock(exit “Timing Mode”) D1 flashing time is forward time(T1) Press and hold the Key for 2 seconds, D2 on, enter the Reverse “setup mode” In Reverse “setup mode”, continuously trigger key twice, D1 off, enter “Standby timer mode” In the “Standby timer mode”, trigger KEY start timing(enter “Timing Mode”) D1 flashing means it is timing(“Timing Mode”) Trigger KEY again to stop the clock(exit “Timing Mode”) D1 flashing time is Reverse time(T2) So far, forward time(T1) and reverse time(T2) is set up Re-power in “work mode”